Views: 4 Author: Site Editor Publish Time: 2020-08-04 Origin: Site
Capsule filling machine resists and adjusts residual capsules
At station 6, the suction and up-and-down push rods are used to remove capsules that are not separated or have other problems. The height of the suction and putter is adjustable and should be adjusted when changing the size of the capsule. The adjustment method of suction nozzle height is: loosen and tighten the top wire to adjust the suction nozzle height up and down, and then tighten the top wire. The suction nozzle should not be too low. If the suction nozzle is too low, the capsule cap opened in the module hole will be sucked up.
The way to adjust the height of the putter is: under the working platform, loosen the lock nut on the joint bearing at both ends of the putter and rotate the putter to adjust the height of the putter. Install the capsules with the body cap not separated in the upper module holes of the fifth and sixth stations, first turn the main motor shaft with the handle to make the push rod move up and down, and observe whether the defective capsules can be removed and sucked out successfully, and then tighten the lock nut. (The putter should be adjusted carefully. When the putter moves up and down, it should not collide with the up and down modules.)